ÖÐÎÄ
Ìṩ5G/2.5G/1G/100M²î±ð½ÓÈëËÙÂÊ£¬£¬£¬£¬£¬£¬£¬Ö§³ÖPoE/PoE+/PoE++µÈ¶àÖÖ¹©µç·½·¨£¬£¬£¬£¬£¬£¬£¬²¢ÓµÓÐ4¸ö25GÉÏÐйâ¿Ú£¬£¬£¬£¬£¬£¬£¬Ìṩ¸üÎÞа×éÍø·½·¨£¬£¬£¬£¬£¬£¬£¬´î½¨¸ßÐÔÄÜÔ°ÇøÍø
ÀàÐÍ£º
24¸öÍòÕ×µç¿Ú£¬£¬£¬£¬£¬£¬£¬4¸öÍòÕ×¹â¿Ú£¬£¬£¬£¬£¬£¬£¬4¸ö25G¹â¿Ú
48¸öÍòÕ×µç¿Ú£¬£¬£¬£¬£¬£¬£¬4¸ö25G¹â¿Ú£¬£¬£¬£¬£¬£¬£¬2¸ö40G¹â¿Ú
48¸ö5Gµç¿Ú£¬£¬£¬£¬£¬£¬£¬4¸ö25G¹â¿Ú£¬£¬£¬£¬£¬£¬£¬2¸ö40G¹â¿Ú
24¸ö5Gµç¿Ú£¬£¬£¬£¬£¬£¬£¬4¸ö25G¹â¿Ú
²úÆ·ÌØÕ÷£º
|
Ó²¼þ¹æ¸ñ |
RG-S6110-24MG4VS-UP |
RG-S6110-48MG4VS2QXS-UP |
RG-S6120-24XMG4XS4VS-UP-H |
RG-S6120-48XMG4VS2QXS-UP-H |
|
½Ó¿Ú¹æ¸ñ |
||||
|
¹Ì»¯ÓªÒµ½Ó¿Ú |
24¸ö100M / 1000M / 2.5G/ 5G×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬4¸ö10G / 25G SFP28¹â¿Ú |
48¸ö100M / 1000M / 2.5G/ 5G×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬4¸ö10G / 25G SFP28¹â¿Ú£¬£¬£¬£¬£¬£¬£¬2¸ö40G QSFP+¹â¿Ú |
24¸ö100M / 1000M / 2.5G / 5G / 10G×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬4¸ö10G SFP+¹â¿Ú£¬£¬£¬£¬£¬£¬£¬4¸ö25G SFP28¹â¿Ú |
48¸ö100M / 1000M / 2.5G / 5G / 10G×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬£¬£¬4¸ö10G / 25G SFP28¹â¿Ú£¬£¬£¬£¬£¬£¬£¬2¸ö40G QSFP+¹â¿Ú |
|
Ä£¿£¿£¿£¿£¿é²å²Û |
ÄÚÖõçÔ´ 2¸ö¹Ì»¯µçÉÈ |
2¸öÄ£¿£¿£¿£¿£¿é»¯µçÔ´²å²Û 3¸öÄ£¿£¿£¿£¿£¿é»¯µçÉȲå²Û |
2¸öÄ£¿£¿£¿£¿£¿é»¯µçÔ´²å²Û 3¸öÄ£¿£¿£¿£¿£¿é»¯µçÉȲå²Û |
2¸öÄ£¿£¿£¿£¿£¿é»¯µçÔ´²å²Û 3¸öÄ£¿£¿£¿£¿£¿é»¯µçÉȲå²Û |
|
¹Ì»¯ÖÎÀí½Ó¿Ú |
1¸öMGMT¶Ë¿Ú 1¸öConsole ¶Ë¿Ú 1¸öUSB¶Ë¿Ú |
1¸öMGMT¶Ë¿Ú 1¸öConsole ¶Ë¿Ú 1¸öUSB¶Ë¿Ú |
1¸öMGMT¶Ë¿Ú 1¸öConsole ¶Ë¿Ú 1¸öUSB¶Ë¿Ú |
1¸öMGMT¶Ë¿Ú 1¸öConsole ¶Ë¿Ú 1¸öUSB¶Ë¿Ú |
|
ϵͳ¹æ¸ñ |
||||
|
½»Á÷ÈÝÁ¿ |
2.56Tbps/25.6Tbps |
|||
|
°üת·¢ÂÊ |
360Mpps/740Mpps |
960Mpps/1360Mpps |
720Mpps/1260Mpps |
1080Mpps/1470Mpps |
|
µçÔ´Ó빦ºÄ |
||||
|
µä·¶¹¦ºÄ |
²»´øPOE¸ºÔع¦ºÄ<110W(Âú¸ººÉ) PoEÂúÔØ¹¦ºÄ<370W(Âú¸ººÉ) |
²»´øPOE¸ºÔع¦ºÄ<200W(Âú¸ººÉ) PoEÂúÔØ¹¦ºÄ<1600W(Âú¸ººÉ) |
²»´øPOE¸ºÔع¦ºÄ<150W(Âú¸ººÉ) PoEÂúÔØ¹¦ºÄ<1650W(Âú¸ººÉ) |
²»´øPOE¸ºÔع¦ºÄ<200W(Âú¸ººÉ) PoEÂúÔØ¹¦ºÄ<1600W(Âú¸ººÉ) |
|
µçÔ´Ä£¿£¿£¿£¿£¿éÐͺŠ|
ÄÚÖõçÔ´ |
RG-PA600I-P-F RG-PA1000P-F |
RG-PA600I-P-F RG-PA1000P-F |
RG-PA600I-P-F RG-PA1000P-F |
|
¶î¶¨ÊäÈëµçѹ |
ÄÚÖõçÔ´ ½»Á÷£¨AC£©ÊäÈë ¶î¶¨µçѹ¹æÄ££º100-240V~ ×î´óµçѹ¹æÄ££º90-264V~ ƵÂÊ£º50/60Hz ÿ·ÊäÈë¶î¶¨µçÁ÷£º6A |
Ö§³ÖµçÔ´ÀàÐÍ£ºRG-PA600I-P-F ½»Á÷£¨AC£©ÊäÈë ¶î¶¨µçѹ¹æÄ££º100-240V~ ×î´óµçѹ¹æÄ££º90-264V~ ƵÂÊ£º50/60Hz ÿ·ÊäÈë¶î¶¨µçÁ÷£º8A
Ö§³ÖµçÔ´ÀàÐÍ£ºRG-PA1000I-P-F ½»Á÷£¨AC£©ÊäÈë ¶î¶¨µçѹ¹æÄ££º100-240V~ ×î´óµçѹ¹æÄ££º90-264V~ƵÂÊ£º50/60Hzÿ· ÊäÈë¶î¶¨µçÁ÷£º8A |
Ö§³ÖµçÔ´ÀàÐÍ£ºRG-PA600I-P-F ½»Á÷£¨AC£©ÊäÈë ¶î¶¨µçѹ¹æÄ££º100-240V~ ×î´óµçѹ¹æÄ££º90-264V~ ƵÂÊ£º50/60Hz ÿ·ÊäÈë¶î¶¨µçÁ÷£º8A
Ö§³ÖµçÔ´ÀàÐÍ£ºRG-PA1000I-P-F ½»Á÷£¨AC£©ÊäÈë ¶î¶¨µçѹ¹æÄ££º100-240V~ ×î´óµçѹ¹æÄ££º90-264V~ƵÂÊ£º50/60Hzÿ· ÊäÈë¶î¶¨µçÁ÷£º8A |
Ö§³ÖµçÔ´ÀàÐÍ£ºRG-PA600I-P-F ½»Á÷£¨AC£©ÊäÈë ¶î¶¨µçѹ¹æÄ££º100-240V~ ×î´óµçѹ¹æÄ££º90-264V~ ƵÂÊ£º50/60Hz ÿ·ÊäÈë¶î¶¨µçÁ÷£º8A
Ö§³ÖµçÔ´ÀàÐÍ£ºRG-PA1000I-P-F ½»Á÷£¨AC£©ÊäÈë ¶î¶¨µçѹ¹æÄ££º100-240V~ ×î´óµçѹ¹æÄ££º90-264V~ƵÂÊ£º50/60Hzÿ· ÊäÈë¶î¶¨µçÁ÷£º8A |
|
×î´óÊäÈëµçѹ |
||||
|
POE½Ó¿Ú |
1~24ºÅ¶Ë¿Ú¾ùÖ§³ÖPoE/PoE+¹©µç£¬£¬£¬£¬£¬£¬£¬Í¬Ê±Ö§³Ö¸ß¹¦ÂÊHPoE¹©µç£¨HPoEµ¥¶Ë¿Ú×î´óÊä³ö¹¦ÂÊ90W£© |
1~48ºÅ¶Ë¿Ú¾ùÖ§³ÖPoE/PoE+¹©µç£¬£¬£¬£¬£¬£¬£¬Í¬Ê±1~24ºÅ¶Ë¿ÚÖ§³Ö¸ß¹¦ÂÊHPoE¹©µç£¨HPoEµ¥¶Ë¿Ú×î´óÊä³ö¹¦ÂÊ90W£© |
1~24ºÅ¶Ë¿Ú¾ùÖ§³ÖPoE/PoE+¹©µç£¬£¬£¬£¬£¬£¬£¬Í¬Ê±Ö§³Ö¸ß¹¦ÂÊHPoE¹©µç£¨HPoEµ¥¶Ë¿Ú×î´óÊä³ö¹¦ÂÊ90W£© |
1~48ºÅ¶Ë¿Ú¾ùÖ§³ÖPoE/PoE+¹©µç£¬£¬£¬£¬£¬£¬£¬Í¬Ê±1~24ºÅ¶Ë¿ÚÖ§³Ö¸ß¹¦ÂÊHPoE¹©µç£¨HPoEµ¥¶Ë¿Ú×î´óÊä³ö¹¦ÂÊ90W£© |
|
µçÉÈÀàÐÍ |
¹Ì»¯Á½¸öµçÉÈ Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§ |
Ö§³ÖÈý¸ö¿É°Î²åÄ£¿£¿£¿£¿£¿é»¯µçÉÈ Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§ |
Ö§³ÖÈý¸ö¿É°Î²åÄ£¿£¿£¿£¿£¿é»¯µçÉÈ Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§ |
Ö§³ÖÈý¸ö¿É°Î²åÄ£¿£¿£¿£¿£¿é»¯µçÉÈ Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§ |
|
³ß´çÓëÖØÁ¿ |
||||
|
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© |
442.0mm x 220.0mm x 43.6mm |
442.0mm x 420.0mm x 43.6mm |
442.0mm x 420.0mm x 43.6mm |
442.0mm x 420.0mm x 43.6mm |
|
²úÆ·ÖØÁ¿ |
7.3kg |
7.3kg |
7.3kg |
7.3kg |
|
ÇéÐÎÓë¿É¿¿ÐÔ |
||||
|
µçÔ´½Ó¿Ú·ÀÀ× |
6KV |
6KV |
6KV |
6KV |
|
ÎÂ¶È¼à¿Ø |
Ö§³Öζȸ澯 |
Ö§³Öζȸ澯 |
Ö§³Öζȸ澯 |
Ö§³Öζȸ澯 |
|
ÊÂÇéÎÂ¶È |
0¡æ~45¡æ |
0¡æ~45¡æ |
0¡æ~45¡æ |
0¡æ~45¡æ |
|
´æ´¢ÎÂ¶È |
-40¡æ~70¡æ |
-40¡æ~70¡æ |
-40¡æ~70¡æ |
-40¡æ~70¡æ |
|
ÊÂÇéʪ¶È |
10%RH~90%RH |
10%RH~90%RH |
10%RH~90%RH |
10%RH~90%RH |
|
´æ´¢Êª¶È |
5%RH~95%RH |
5%RH~95%RH |
5%RH~95%RH |
5%RH~95%RH |
|
Èí¼þ¹æ¸ñ |
RG-S6110-24MG4VS-UP |
RG-S6110-48MG4VS2QXS-UP |
RG-S6120-24XMG4XS4VS-UP-H |
RG-S6120-48XMG4VS2QXS-UP-H |
|
VLAN |
Ö§³Ö4K 802.1Q VLAN Ö§³ÖPort based VLAN Ö§³ÖPrivate VLAN Ö§³ÖGVRP Ö§³ÖSuper VLAN |
|||
|
QinQ |
Ö§³Ö»ù±¾QinQ¡¢Ö§³ÖÎÞаQinQ |
|||
|
Á´Â·¾ÛºÏ |
Ö§³ÖLACP(802.3ad) |
|||
|
¶Ë¿Ú¾µÏñ |
Ö§³Ö»ùÓÚÁ÷µÄ¾µÏñ Ö§³Ö¶à¶ÔÒ»¶Ë¿Ú¾µÏñ¼°Ò»¶Ô¶à¶Ë¿Ú¾µÏñ Ö§³ÖRSPAN Ö§³Ö¾ÛºÏÁ´Â·µÄ¾µÏñ |
|||
|
ÌìÉúÊ÷ |
Ö§³ÖSTP¡¢RSTP¡¢MSTP |
|||
|
DHCP |
Ö§³ÖDHCP Server Ö§³ÖDHCP Client Ö§³ÖDHCP Snooping Ö§³ÖDHCP Relay Ö§³ÖIPv6 DHCP Snooping Ö§³ÖIPv6 DHCP Client Ö§³ÖIPv6 DHCP Relay |
|||
|
IPv6»ù´¡ÐÒé |
IPv6±àÖ·¡¢ICMPv6¡¢Path MTU Discovery |
|||
|
IP·ÓÉ |
Ö§³Ö¾²Ì¬Â·ÓÉ Ö§³ÖRIP£¬£¬£¬£¬£¬£¬£¬RIPng Ö§³ÖOSPFv2£¬£¬£¬£¬£¬£¬£¬OSPFv3£¬£¬£¬£¬£¬£¬£¬IS-ISv4£¬£¬£¬£¬£¬£¬£¬IS-ISv6 Ö§³ÖBGP4£¬£¬£¬£¬£¬£¬£¬BGP4+ Ö§³ÖµÈ¼Û·ÓÉ |
|||
|
×é²¥ |
Ö§³ÖIGMP v1£¬£¬£¬£¬£¬£¬£¬v2£¬£¬£¬£¬£¬£¬£¬v3£¬£¬£¬£¬£¬£¬£¬IGMPÊðÀí Ö§³ÖIGMP v1£¬£¬£¬£¬£¬£¬£¬v2 Ö§³ÖIGMP ¹ýÂË£¬£¬£¬£¬£¬£¬£¬IGMP¿ìËÙÍÑÀë Ö§³ÖPIM-DM£¬£¬£¬£¬£¬£¬£¬PIM-SM£¬£¬£¬£¬£¬£¬£¬PIM-SSM Ö§³ÖMLD Snooping£¬£¬£¬£¬£¬£¬£¬MLD Ö§³ÖMSDP |
|||
|
ACL |
Ö§³ÖÎÞа¶àÑùµÄÓ²¼þACL£º Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØµãµÄÓ²¼þACL£© Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØµã¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£© Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØµã¡¢Ä¿µÄMACµØµãºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£© Ö§³Ö»ùÓÚʱ¼äACL Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØµã¡¢IPµØµã¡¢TCP/UDP¶Ë¿ÚºÅ¡¢ÐÒéÀàÐÍ¡¢Ê±¼äµÈÎÞа×éºÏµÄÓ²¼þACL£© Ö§³ÖACL80 Ö§³ÖIPv6 ACL |
|||
|
QoS |
Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ Ö§³Ö802.1p/DSCP/ToSÁ÷Á¿·ÖÀà ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WRR¡¢SP+DRR¡¢RED/WREDÐÐÁе÷Àí |
|||
|
Çå¾²ÌØÕ÷ |
¹ýÂ˲»·¨µÄMACµØµã Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»£»£»£»£»¤ Ö§³ÖRADIUS ºÍ TACACS+ Ö§³ÖSSH Ö§³ÖBPDU Guard Ö§³ÖCPP¡¢NFPP |
|||
|
ÖÎÀíÌØÕ÷ |
SNMP¡¢CLI(Telnet/Console)¡¢RMON(1,2,4,9)¡¢Syslog¡¢NTP¡¢SNMP over IPv6¡¢IPv6 MIB support for SNMP ¡¢Telnet v6¡¢FTP/TFTP v6¡¢DNS v6¡¢NTP for v6¡¢Traceroute v6 Ö§³ÖsFLOW£¬£¬£¬£¬£¬£¬£¬¿ÉʹÓÃÊý¾ÝÁ÷Ëæ»ú²ÉÑùÊÖÒÕ£¬£¬£¬£¬£¬£¬£¬¶Ô½»Á÷»úµÄÁ÷Á¿¾ÙÐÐÁ÷ÐÅÏ¢²ÉÑù |
|||
|
¸ß¿É¿¿ÐÔ |
Ö§³ÖVSU£¨ÐéÄ⻯ÊÖÒÕ£¬£¬£¬£¬£¬£¬£¬½«¶ą̀װ±¸ÐéÄâ³É1̨£©¡¢Ö§³ÖGR for RIP/OSPF/BGPµÈ·ÓÉÐÒé¡¢Ö§³ÖBFD¼ì²â¡¢Ö§³ÖREUP¡¢Ö§³ÖRLDP¡¢Ö§³ÖµçÔ´1+1ÈßÓ౸·Ý¡¢µçÔ´Ä£¿£¿£¿£¿£¿é¡¢µçÉÈÄ£¿£¿£¿£¿£¿éÖ§³ÖÈȲå°Î¹¦Ð§ |
|||